WIRING
ENCLOSURE ‘W’
Cable Glands and adaptors
If enclosure ‘W’ is supplied with a through hole of 22 mm
blanked with a blind grommet. Discard the grommet and fit a suitable proprietary brass or
nylon M20 cable gland wi
th thread length of 10 mm and locknut. Fit the nylon reducer provided
to the inside and a fibre washer to the outside. See diagram 1.
Alternately, the enclosure may be supplied from the factory with a threaded adaptor ready to
accept the customer’s gland or conduit system.
Alternatives:
i) a metal or nylon adaptor may be used to accommodate other sizes of gland eg NPT, or
conduit system. See diagram 2.
ii) an elbow kit may be supplied to enable the entry to be rotated axially through 90
° and
radially through 36. See diagram 3.
Earthing / grounding
The user must make suitable local earthing arrangements, if required,
to ensure that metal glands are earthed.
An earthing point is provided inside the enclosure. If this is disturbed in any way it must b
e
reassembled correctly to be an effective earth and prevent ingress. See diagram 4. When
removing the lid slacken the M4 nut first and ensure it is re tightened whenever the lid is
replaced. See diagram 4.1.
ENCLOSURE ‘A
Cable Glands and adaptors – E
nclosure ‘A’ is supplied with an M20 x 1.5 tapped hole. Use a
suitable stainless steel cable gland and sealing washer. Alternately the enclosure may be
supplied with a threaded adaptor fitted at the factory ready to accept the customer’s gland or
conduit system. See diagram 5.
Earthing / grounding
Bonding between the enclosure and gland / adaptor will be achieved
when both parts are screwed together. An earthing point is provided inside the enclosure. If
this is disturbed in any way it must be reas
sembled correctly to be an effective earth and
prevent ingress. See diagram 4.
EARTHING / GROUNDING OF PROCESS CONNECTION AND BACK PLATES
All the
internal dead metal work is bonded to the enclosure earthing point. Due to requirements of
sealing, the p
rocess connection and back plates may be isolated from the earthing point. Do
not, therefore, rely on either for earthing, instead always use the earthing point provided. If
required, the process connection and back plates may be bonded locally. Never u
se the
process connection or inlet pipe for locally grounding welding equipment unless it is separately
earth bonded.
Pollution degree
all products are suitable for use in pollution degree 3. Fo
r extreme
conditions where condensation may readily form, then sealed contacts should be used. See
Table A codes 08/09, 0G/0H, H2/H3/H6.
Electrical isolation
These products are not suitable for electrical isolation. Always isolate
circuit separately to carry out any electrical work.
TABLE A – MICROSWITCH RATINGS
IEC 947-5-1 / EN 60947-5-1 RATING
VA
S W I T C H
C O D E
U L / C S A
M I C R O S W I T C H
R A T I N G
( R E S I S T I V E )
* S E E N O T E
Uimp
Ui
R A T I N G
( I e I U e )
D e s i g n a t i o n
&
U t i l i s a t i o n
C a t e g o r y
Ma ke
Br eak
5 A @ 1 1 0 / 2 5 0
V A C
0 . 6 / 0 . 3 A @
1 2 0 / 2 4 0 V A C
A C 1 4 /
D 3 0 0
A C 4 3 2
7 2
0 . 8 k V
2 5 0
V
0 0
&
0 1
0 . 2 2 / 0 . 1 A @
1 2 5 / 2 5 0 V D C
D C 1 3 /
R 3 0 0
D C
2 8 2 8
5 A @ 1 1 0 / 2 5 0
V A C
0 . 6 / 0 . 3 A @
1 2 0 / 2 4 0 V A C
A C 1 4 /
D 3 0 0
A C
4 3 2 7 2
0 . 8 k V
2 5 0 V
0 2
&
0 3
2 A @ 3 0 V D C
0 . 2 2 / 0 . 1 A @
1 2 5 / 2 5 0 V D C
D C 1 3 /
R 3 0 0
D C
2 8 2 8
1 A @ 1 2 5 V A C
1 A @ 1 2 5 V AC R E S I S TI VE ( IE C 1 0 58 - 1 / E N 6 1 0 58 - 1)
0 4
&
0 5
* 1 0 0 m A @ 3 0
V D C
* 5 A @
1 1 0 / 2 5 0 V A C
0 . 6 / 0 . 3 A @
1 2 0 / 2 4 0 V A C
A C 1 4 /
D 3 0 0
A C
4 3 2 7 2
0 . 5 k V
2 5 0 V
0 8
&
0 9
5 A @ 3 0 V D C
0 . 2 2 / 0 . 1 A @
1 2 5 / 2 5 0 V D C
D C 1 3 /
R 3 0 0
D C
2 8 2 8
* 1 A @ 3 0 V A C
A C 1 4 /
E 1 5 0
A C
2 1 6 3 6
0 . 5 k V
1 2 5 V
0 . 3 A @ 1 2 0
0 G
&
0 H
& 3 0 V D C
V A C
0 C
5 A @ 1 1 0 / 2 5 0
V A C
0 . 8 k V
2 5 0 V
0 . 6 / 0 . 3 A @
1 2 0 / 2 4 0
V A C
A C 1 4 /
D 3 0 0
A C
4 3 2 7 2
5 A @ 1 1 0 / 2 5 0
V A C
0 . 6 / 0 . 3 A @
1 2 0 / 2 4 0 V A C
A C 1 4 /
D 3 0 0
A C
4 3 2 7 2
0 . 8 k V
2 5 0 V
0 D
2 A @ 3 0 V D C
0 . 2 2 / 0 . 1 A @
1 2 5 / 2 5 0 V D C
D C 1 3 /
R 3 0 0
D C
2 8 2 8
5 A @ 1 1 0 / 2 5 0
V A C
0 . 6 / 0 . 3 A @
1 2 0 / 2 4 0 V A C
A C 1 4 /
D 3 0 0
A C
4 3 2 7 2
0 . 5 k V
2 5 0 V
H 2
&
H 3
&
H 6
2 A @ 3 0 V D C
0 . 2 2 / 0 . 1 A @
1 2 5 / 2 5 0 V D C
D C 1 3 /
R 3 0 0
D C
2 8 2 8
The electrical rating is dependent on the microswitch fitted to
the instrument. The electrical rating is defined by each
approval that the microswitch complies with and is shown on
the product nameplate, ie UL / CSA, or IEC. It should be
noted that the switch must be used within the electrical rating
specified from the approval you require. Table A lists the
actual IEC ratings against the Designation & Utilisation
Category marked on the nameplate. In the absence of any
verification by UL / CSA the microswitch *manufacturers
rating is specified in bold italics. If in doubt, seek guidance
from factory.
ENCLOSURE WALL
LOCKNUT
NYLON 22/20
REDUCER
FIBRE WASHER
PROPRIETARY
GLAND
DIAG 1
‘W CABLE GLAND ASSY
CABLE GLAND /
CONDUIT ADAPTOR
DIAG 2
‘WADAPTOR ASSY
GLAND
SCREW
FIBRE
WASHER
O RING
SEAL
½" NPT Pg 13.5
M20 X 1.5 ¾ ET
ENCLOSURE
WALL
DIAG 3
ELBOW ASSY
M4 PLAIN
WASHER
M4 SCREW
EARTH
STRAP
M4 STUD
M4 SINGLE
COIL WASHER
M4 NUT
LID
BASE
GASKET
DIAG 4.1
EARTH STRAP
ENCLOSUREM20 x 1.5
FIBRE WASHER
ADAPTOR
DIAG 5
A ADAPTOR
EARTH LABEL
ENCLOSURE W ALL
(EXTERIOR)
SCREW
BONDED SEAL
SINGLE
COIL
W ASHER
PLAIN
WASHERS
STAR W ASHER
NUT
NUT
DIAG 4
EARTHING ASSY
Low Voltage Directive (LVD)
2006/95/AC.
Switch products with enclosure codes
‘W’ and ‘A’ supplied CE-
marked must be installed and used in accordance with the
main instructions and this addendum supplied with each product. Products rated
lower t
han 50V ac and 75 V dc are outside the scope of the LVD, and therefore, do
not require CE-
marking under this directive. The LVD does not apply to products
with enclosure codes ‘H’, ‘K’, ‘R’, ‘M’, ‘N’ for use in hazardous areas. Switch products
with enclosu
re codes ‘H’, ‘K’, ‘R’, ‘M’, ‘N’, are covered by the Explosive Atmospheres
Directive ATEX 94/9/EC and when CE-
marked will indicate compliance with this
directive alone. The following directives do not apply to switch products
manufactured by Delta Controls:
Electromagnetic Compatibility EMC 2004/108/EC
Machinery Safety Directive MSD
2006/42/EC
Declaration of Conformity
We: Delta Controls Ltd
Island Farm Avenue
West Molesey
Surrey, UK
KT8 2UZ
As the manufacturers of the apparatus listed, declare under our sole responsibility that the products listed
below:
Pressure, Pressure Difference, Temperature & Flow switches series “W” or “A”:
201, 202, 203, 281, 204, 207, 208, 209, 231, 232, 233, 234, S21, S22, S24, GR2, GR4, VM2, VM4.
301, 303, 304, 381, 384, 306, 386, 310, 316, S31, S34, GR3, GR6.
721, 731, 771, 722, 732, 772, 723, 733, 773, 781, 734, 774, 741, 742, 743, 744, S71, GR7.
131.
To which this declaration relates are in conformity with the following relevant standards or parts thereof:
EN 60947-1 :1992 Low voltage switch gear and control-gear-general rules.
EN 60947-5-1:1992 Low voltage switch gear and control-gear-control circuit devices and switching
elements.
EN 60529: 1991 Specification for classification of degrees of protection provided by enclosures.
EN 60950:1992 Safety of information technology equipment including electrical business equipment:
section 2.5.
BS 6134:1991 Specification for pressure and vacuum switches.
And thereby conforms to the requirements of the Low Voltage Directive 73/23/EC amended by 93/68/EEC.
Signed:
………………….
R. Harrison
Managing Director
Original dated 22
nd
June 2000
Rev. B dated 12
th
August 2009
Zobrazit stránku 1
1 2

Komentáře k této Příručce

Žádné komentáře